Product features
Full-automatic testing meter. You just need a digital set. Setting the test of maximum output voltage current and step size. The output voltage could be raised from zero to setting voltage step-by-step automatically. The test data is recorded automatically, volt-ampere characteristics is depicted automatically .The test process is instant precise, simple, convenient.
High output capacity. In volt-ampere characteristics Measurement, Maximum output: 1000V, 20A. Maximum Current is to 600A in Ratio test.
Equipped Graphical LCD screen, English menu. The volt-ampere characteristics data and curve is displayed directly during the test process. A micro printer is mounted on front panel, the data and curve can be printed at once.
There is not any key, button. Equipped with an optical mouse, it's convenient and effective.
High precision test In. the output range of measurement, the accuracy is below 0.5% output range of measurement, the accuracy is below 0.5% for voltage and current.
Powerful Function. 10% Error burden-curve, volt-ampere characteristics and ratio polarity can be measured. FAC-II can be easily connect to PC, the tested data can be send to PC and saved in PC, FAC_II also can be controlled by the PC software.
Optional external step-up transformer , external current generator. Output voltage of the external step-up transformer can be as high as up to 2000V, the capacity of the external step up transformer is 2000V/2A.
High-capacity Storage. 45 groups tested data can be saved in FAC-II, the data is battery backup. Data won't be lost when Power is off. You can print the saved data or send the tested data to PC for more analyzing.
Duplex operation. The RS232 or U tray Communication Interface can be connected with PC. The data could be saved, displayed, edited and printed.
Weight: 26Kg
Size: Length40cm width 30cm height 34cm. The tester is portable and convenient.
Technical Data
input voltage |
AC 380 V |
AC 220 V |
Distinguish grade |
CT Volt-Ampere test |
stand-alone test |
model A |
0 ~ 950 V , 0 ~ 25 A |
0 ~ 550 V , 0 ~ 25 A |
1mV , 1mA |
model B |
0 ~ 950 V , 0 ~ 20 A |
0 ~ 550 V , 0 ~ 20 A |
external rise transform |
0 ~ 2500 V , 0 ~ 1.5 A |
0 ~ 2500 V , 0 ~ 1.5 A |
1mV , 1mA |
provide for oneself rise transform |
0 ~ 5000 V , 0 ~ 25 A |
1mV , 1mA |
CT Ratio
test |
one loop current |
stand-alone test |
model A : 0 ~ 750A model B : 0 ~ 600A |
1mA |
external rise current transform |
0 ~ 1000A |
1mA |
provide for oneself rise current transform |
0 ~ 2000 A |
1mA |
two loop current |
0 ~ 5 A |
1mA |
CT two loop load test |
two loop current |
0 ~ 5 A |
1mA |
two loop impedance |
0 ~ 4 Ω |
0.001 Ω |
PT Volt-Ampere test |
output voltage |
0 ~ 200 V |
1mV |
output current |
0 ~ 20 A |
1mA |
PT
Ratio
test |
one loop voltage |
stand-alone test |
0 ~ 1000 V |
0 ~ 550 V |
1mV |
external rise transform |
0 ~ 2500 V |
0 ~ 2500 V |
1mV |
provide for oneself rise transform |
0 ~ 5000 V |
1mV |
two loop voltage |
0 ~ 20 V |
1mV |
measure precision |
Volt-Ampere test |
< 0.5% |
5% and10%error curve |
< 1% |
Ratio test |
< 0.5% |
angle difference test |
< 1% |
two loop load test |
< 0.5% |
power supply voltage |
AC 220 V / AC 380V , 50 ~ 60 Hz |
work condition temperature |
-10 -+ 50 |
Tester mainframe cubage |
model A : 450*340*320 cube mm model B : 400*300*320 cube mm |
Tester mainframe weight |
model A : 39 Kg model B : 28 Kg |
|
|
|
|
|
|
|